Start of MHD5

science/mhd

Image1703

In hydraulic analogy, the propagation of a normal shock wave is equivalent to that of a "breaking wave." How do we create this? Simply by placing a small water height in section B and a larger water height in section A. In the expansion tank: nothing, absolutely no water. In cross-section:

Image1704

Everything is ready for the test. The sluice barrier is removed very quickly. The colored water mass (for example, using fluorescein) bursts into the downstream channel. This is what we obtain:

Image1705

What do we observe? The onset of a breaking wave, a liquid wave front, which sets the clear water into motion. But the wave front moves faster than the water itself.

Image1706

Downstream, a rarefaction wave begins, but much "softer." This is not a shock wave.

Image1707

Shortly afterward, the situation is as follows:

Image1708

The rarefaction wave reaches the bottom of the "tank." The distance between the clear water "pushed" into motion and the interface has increased. We therefore have a usable "gust," where clean water has been set in motion, thus increasing the height (hydraulic analog of pressure in a gas). We can therefore "work" on this gust. Later, the rarefaction wave reflects off the tank bottom and quickly catches up with the entire interface-wave front.

Image1709

We see that if we had installed an "observation window" in the wall, we would have seen the clean water mass, set in motion, pass through during the "gust duration." The entire process can be read on an "x,t" diagram:

Image1710

Here we have a faithfully analogous image of the operation of a "shock tube." It suffices to replace the sluice with a "high-pressure chamber." The sluice barrier, manually operated, becomes a copper diaphragm that opens when sufficient pressure is reached (using a combustion chamber). The test channel becomes a test tube of constant cross-section, initially filled with argon at low pressure (13 mm Hg). As for the expansion tank, it is simply a vacuum reservoir of any shape. The paper barrier is replaced by a mylar membrane, which ruptures when the shock wave reaches it. Below is a schematic layout of the installation:

Image1711

Length of the high-pressure chamber: 1.4 meters. Diameter (same as the test section): 5.6 cm. Length of the test section: 6 meters. At the bottom, the red copper membrane, weakened by grooves, opens into four petals, allowing the hot gas to pass freely. The high-pressure chamber is filled with a H2 + 1/2 O2 mixture, with helium as a diluent. The expansion tank is simply a sturdy container capable of sustaining a vacuum. The setup is completed with various rotary vacuum pumps, commonly available secondhand, capable of achieving vacuums below 10-2 mm Hg (10-2 torr), along with vacuum-tight valves. Add a set of gas cylinders supplying hydrogen, oxygen, helium, and of course argon.

Image1712

The combustible gas mixture is ignited by a system of spark plugs connected to a high-voltage source. Since this system generates electromagnetic interference, the entire high-pressure assembly is enclosed in a Faraday cage (wooden frame and copper mesh, 1 mm mesh). Rustic, but effective. The six meters of low-pressure argon are transformed into a compressed gas plug (1 bar) and hot (10,000 K), about twenty centimeters long. This is immediately followed by the "burned gases," i.e., a mixture of water vapor and helium.

Image1713

That concludes the "hot-gust wind tunnel" section.

Image1714

In the test section where measurements are taken and the actual MHD experiment is performed, the cross-section is square (5 cm by 5 cm). Therefore, a carefully machined piece must be inserted to transition from a circular to a square cross-section:

Image1715

The MHD nozzles can be made from acrylic (with glued parts) or laminated plastic (for strength), and equipped with a high-quality optical window. Although the argon temperature is high, it does not damage the nozzle components due to the brevity of the gust (80 millionths of a second).

To generate a transverse magnetic field, two solenoids will be used, arranged as shown below:

In the following drawing, one solenoid has been removed to show the placement of the model (lenticular airfoil):

The volume of the MHD nozzle, including its overall size, is on the order of one liter, and the magnetic field to be generated must reach 20,000 gauss (2 teslas), requiring a very high current (50,000 amperes) through the solenoid windings. Such a current tends to explode the solenoids—not due to Joule heating—but simply because of the J × B forces acting within the windings themselves. The copper windings will need to be reinforced with a kind of "corset," for example, made of fiberglass embedded in araldite.

Since the actual MHD interaction experiment is very brief, an economical solution to generate such high currents is to use a bank of capacitors discharged into this inductor (oscillatory discharge). It is sufficient to synchronize the system so that the experiment (at the moment the hot argon gust passes) occurs when the magnetic field B is nearly stationary (discharge period: 5 milliseconds).

Next drawing: the shock wave wind tunnel equipped for MHD experiments, as it appeared in my laboratory in the 1960s.

The capacitors were charged to 5 kV. A smaller bank of capacitors then powers the test model's electrodes.

Problem: how to switch 50,000 amperes? Answer: by using an old electric locomotive ignitron (designed to switch 2,000 amperes, but robust enough to withstand hundreds of tests at 25 times that current). Ignitrons are well known to power electronics specialists.